Allen-Bradley 1756-CPR2U 冗余电源电缆 系统中传输电力
【产品详情】
制造者 | 罗克韦尔自动化 |
品牌 | 艾伦-布拉德利 |
零件号/目录号 | 型号:1756-CPR2U |
系列 | ControlLogix |
电缆长度 | 3英尺(0.91米) |
长度 | 10英尺(3米) |
重量 | 0.2千克(0.3磅) |
Allen-Bradley 1756-CPR2U 是一款 1756 直角冗余电源电缆,用于在 ControlLogix 系统中传输电力。与标准电源相比,冗余电源具有各种附加功能。其中一些是自动机箱负载分配、运行状态指示灯、固态继电器,以及仅限于电源(不包括电缆和适配器)的运行异常。
1756-CPR2U 冗余电源电缆的电缆长度为 0.91 米(3 英尺),重量为 0.3 磅。它在 5.1V DC 时的输入电流为 970 mA,在 24V DC 时为 1.7 mA。它支持每秒 5 兆比特的 ControlNet 通信。1756-CPR2U 的最大功耗为 5.1 W,散热为每小时 17.4 BTU。它安装在带有开放式外壳和 4 英寸的机箱中。顶部和侧面的间隙为 (101.6 mm)。
1756-CPR2U 冗余电源电缆已将冗余电源所需的最小安装尺寸从超过 5 英寸(152.4 毫米)减少到小于 2 英寸(50.8 毫米)。它支持 ControlLogix 系统中所有系列的标准冗余电源。XT 电缆适配器和电源与之兼容。1756-CPR2U 符合 RoHS(有害物质限制)标准,成本与其他标准电缆相同。
Allen-Bradley 1756-CPR2U 冗余电源电缆 系统中传输电力
【英文介绍】
The Allen-Bradley 1756-CPR2U is a 1756 right-angle redundant power cable for transmitting power in ControlLogix systems. Compared with standard power supplies, redundant power supplies have various additional functions. Some of these are automatic chassis load distribution, operating status indicators, solid-state relays, and operating exceptions limited to the power supply (excluding cables and adapters).
The 1756-CPR2U redundant power cable has a cable length of 0.91 m (3 ft) and a weight of 0.3 lb. It has an input current of 970 mA at 5.1V DC and 1.7 mA at 24V DC. It supports ControlNet communications at 5 megabits per second. The 1756-CPR2U has a maximum power consumption of 5.1W and a heat dissipation of 17.4 BTU per hour. It is installed in a 4-inch case with an open housing. The gap between the top and sides is (101.6 mm).
The 1756-CPR2U redundant power cable has reduced the minimum mounting size required for redundant power supplies from more than 5 inches (152.4 mm) to less than 2 inches (50.8 mm). It supports all families of standard redundant power supplies in ControlLogix systems. XT cable adapters and power supplies are compatible. The 1756-CPR2U is RoHS (Restriction of Hazardous Substances) compliant and costs the same as other standard cables.
Allen-Bradley 1756-CPR2U 冗余电源电缆 系统中传输电力
【其他型号推荐】
The Allen-Bradley 1756-CPR2U is a 1756 right-angle redundant power cable for transmitting power in ControlLogix systems. Compared with standard power supplies, redundant power supplies have various additional functions. Some of these are automatic chassis load distribution, operating status indicators, solid-state relays, and operating exceptions limited to the power supply (excluding cables and adapters).
The 1756-CPR2U redundant power cable has a cable length of 0.91 m (3 ft) and a weight of 0.3 lb. It has an input current of 970 mA at 5.1V DC and 1.7 mA at 24V DC. It supports ControlNet communications at 5 megabits per second. The 1756-CPR2U has a maximum power consumption of 5.1W and a heat dissipation of 17.4 BTU per hour. It is installed in a 4-inch case with an open housing. The gap between the top and sides is (101.6 mm).
The 1756-CPR2U redundant power cable has reduced the minimum mounting size required for redundant power supplies from more than 5 inches (152.4 mm) to less than 2 inches (50.8 mm). It supports all families of standard redundant power supplies in ControlLogix systems. XT cable adapters and power supplies are compatible. The 1756-CPR2U is RoHS (Restriction of Hazardous Substances) compliant and costs the same as other standard cables.