该装置属于伍德沃德公司负载共享装置的一部分。该装置被指定为 9907-173 型号的同步和下垂负载分配装置。这些装置的开发和生产是为了连接和安装在 Caterpillar 型号发动机上,并配备了类似生产的数字速度组件。这些引擎处理脉宽调制输入。当伍德沃德负载分配模块连接到它时,这也允许集成其他伍德沃德生产的零件。它还划分了 Caterpillar 发动机和速度控制模块以及伍德沃德电子控制装置之间的负载分配。
该模块所需的电源进气量范围在 18 至 32 V/DC 的最小进气量之间,或者 5 瓦。它具有高达 -32 V/DC 的反向电压保护,以及高达 80 V/DC 的欠压和过压保护。有 PT 和 CT 三相输入。PT 输入需要 100 至 240 V/AC 线对线,而 CT 输入在满载时需要 3 至 7 A Rms。应该注意的是,该设备只能在包含符合所述指令和 CE 标志要求的发动机原动机系统的情况下使用。
Woodward 9907-173 负载均分模块 发动机分担负载
【英文介绍】
The unit is part of Woodward's load sharing unit. The unit is designated as a synchronous and droop load distribution unit for model 9907-173. These units were developed and manufactured to attach and mount on Caterpillar model engines and are equipped with production-like digital speed components. These engines handle pulse width modulation inputs. This also allows for the integration of other Woodward-produced parts when Woodward load distribution modules are connected to it. It also divides the load distribution between the Caterpillar engine and the speed control module and the Woodward electronic control unit.
The required power intake for this module ranges from a minimum intake of 18 to 32 V/DC, or 5 watts. It has reverse voltage protection up to -32 V/DC, and undervoltage and overvoltage protection up to 80 V/DC. There are PT and CT three-phase inputs. PT inputs require 100 to 240 V/AC wire-to-wire, while CT inputs require 3 to 7 A Rms at full load. It should be noted that the equipment can only be used if it contains an engine prime mover system that complies with the requirements of the said directive and the CE marking.
Woodward 9907-173 负载均分模块 发动机分担负载
【其他型号推荐】
The unit is part of Woodward's load sharing unit. The unit is designated as a synchronous and droop load distribution unit for model 9907-173. These units were developed and manufactured to attach and mount on Caterpillar model engines and are equipped with production-like digital speed components. These engines handle pulse width modulation inputs. This also allows for the integration of other Woodward-produced parts when Woodward load distribution modules are connected to it. It also divides the load distribution between the Caterpillar engine and the speed control module and the Woodward electronic control unit.
The required power intake for this module ranges from a minimum intake of 18 to 32 V/DC, or 5 watts. It has reverse voltage protection up to -32 V/DC, and undervoltage and overvoltage protection up to 80 V/DC. There are PT and CT three-phase inputs. PT inputs require 100 to 240 V/AC wire-to-wire, while CT inputs require 3 to 7 A Rms at full load. It should be noted that the equipment can only be used if it contains an engine prime mover system that complies with the requirements of the said directive and the CE marking.