IC660BBA020 组合模拟I/O模块

【产品详情】 IC660BBA020是一个天才I/O块。该模块是一个组合模拟I/O模块,具有四(4)个模拟输入通道,可容纳0-10 VDC, 10 VDC, 5 VDC, 0-5 VDC, 4 - 20 mA(或1-5 VDC)输入信号和两(2)个模拟输出通道,支持0-10 VDC, 10 VDC, 5 VDC, 0-5 VDC, 4 - 20 mA(或1-5 VDC)。它具有集成的转换器电路,

联系人:Sunny

手机:18059884797

QQ:3095989363

邮箱:xiongbagk@gmail.com

产品详情

IC660BBA020 组合模拟I/O模块


 

IC660TSA100.jpg


【产品详情】

 

IC660BBA020是一个天才I/O块。该模块是一个组合模拟I/O模块,具有四(4)个模拟输入通道,可容纳0-10 VDC, 10 VDC, 5 VDC, 0-5 VDC, 4 - 20 mA(或1-5 VDC)输入信号和两(2)个模拟输出通道,支持0-10 VDC, 10 VDC, 5 VDC, 0-5 VDC, 4 - 20 mA(或1-5 VDC)。它具有集成的转换器电路,转换器分辨率为12位分辨率加号。


该模块独立供电,输入电压18- 56vdc,标称电源24vdc。它具有对天才总线协议的嵌入式支持,允许该模块通过网络与天才总线主机交换I/O数据。每个通道具有每4毫秒的更新率,并配有软件可调的滤波器响应,8,16,32,64,128,256,512和1024mS。输入滤波器用于稳定接收到的输入信号,限制波动和更可用的读数。它还提供了自诊断能力,能够检测范围过小,范围过广,高报警和低报警。它还具有可配置的开线输出设置,允许信号在检测时过量程和过量程。IC660BBA020的典型精度为满量程的0.2%,最大为满量程的0.5%。


IC660BBA020为开放式插框设计,因此必须安装在插框内。环境应清洁,无空气污染物,通风良好。该模块支持右侧向上或倒置安装。如果使用多个块,至少2英寸的间隙之间必须存在。


IC660BBA020模拟I/O模块是GE发那科I/O模块,具有4个输入电路,2个输出电路和2个模块版本。它提供5个模拟功率范围,分别为0至10伏DC, -5伏DC至+5伏DC, -10伏DC至+10伏DC, 0至5伏DC和4至20毫安/1至5伏DC。IC660BBA020模拟I/O块还为单个输入和输出通道提供独立的缩放和故障报告功能。模块在25摄氏度时的典型热漂移是每摄氏度10 PPM。用户可以使用任何GE发那科IC66手持监视器与这个GE I/O块模块。它还提供高级诊断工具来生成故障消息。


IC660BBA020模拟I/O模块可用于各种输入和输出设备,如按钮,继电器,传感器和工业操作员接口。为了给模块上电,可以从外部使用24伏或48伏的直流电源。该模块的输入电路负责将接收到的电压或电流值转换为12位数字值。换算设施可将最终数值转换为工程单位。输出通道根据来自CPU的转换数字值提供模拟电压或电流值。IC660BBA020模拟I/O模块在其面板上带有2个状态指示led。由于本模块为开放式设备,请将其安装在防护框内。安装区域应保持清洁,无腐蚀性物质。电源应接在6号和7号端子上。


 

IC660BBA020 组合模拟I/O模块


IC660TSA100.jpg

 

英文介绍

 

IC660BBA020 is a genius I/O block. The module is a combined analog I/O module with four (4) analog input channels that can accommodate 0-10 VDC, 10 VDC, 5 VDC, 0-5 VDC, 4-20 mA(or 1-5 VDC) input signals and two (2) analog output channels. Supports 0-10 VDC, 10 VDC, 5 VDC, 0-5 VDC, 4-20 mA(or 1-5 VDC). It has an integrated converter circuit with a resolution of 12 bit resolution plus sign.


The module has independent power supply, input voltage 18-56vdc, nominal power supply 24vdc. It has embedded support for the Genius Bus protocol, allowing the module to exchange I/O data with the Genius Bus host over the network. Each channel has an update rate every 4 milliseconds and is equipped with software-adjustable filter responses of 8,16,32,64,128,256,512 and 1024mS. The input filter is used to stabilize the received input signal, limiting fluctuations and more usable readings. It also provides self-diagnostic capabilities, capable of detecting too small a range, too wide a range, high alarm and low alarm. It also has a configurable open-wire output setting that allows the signal to overrange and overrange during detection. The typical accuracy of IC660BBA020 is 0.2% of full scale, up to 0.5% of full scale.


The IC660BBA020 is an open enclosure design, so it must be installed in the enclosure. The environment should be clean, free of air pollutants and well ventilated. The module can be mounted on the right side up or upside down. If multiple blocks are used, a gap of at least 2 inches must exist between them.


The IC660BBA020 analog I/O module is a GE Fanuc I/O module with 4 input circuits, 2 output circuits, and 2 module versions. It offers five analog power ranges of 0 to 10 volts DC, -5 volts DC to +5 volts DC, -10 volts DC to +10 volts DC, 0 to 5 volts DC and 4 to 20 MA /1 to 5 volts DC. The IC660BBA020 analog I/O block also provides independent scaling and fault reporting capabilities for individual input and output channels. The typical thermal drift of the module at 25 degrees Celsius is 10 PPM per degree Celsius. Users can use any GE Fanuc IC66 handheld monitor with this GE I/O block module. It also provides advanced diagnostic tools to generate fault messages.


The IC660BBA020 analog I/O module can be used in a variety of input and output devices such as buttons, relays, sensors and industrial operator interfaces. In order to power the module, a 24 volt or 48 volt DC power supply can be used from the outside. The input circuit of the module is responsible for converting the received voltage or current value to a 12-digit digital value. Conversion facilities convert final values into engineering units. The output channel provides an analog voltage or current value based on the converted digital value from the CPU. The IC660BBA020 analog I/O module has 2 status indicator leds on its panel. As this module is an open device, please install it in the protective frame. The installation area should be kept clean and free of corrosive substances. The power supply should be connected to terminals 6 and 7.


 

IC660BBA020 组合模拟I/O模块


f14436c0-1164-4faa-8d17-523c0942bd1e~0.jpg

F$GC2U(@SRY@1IFCS[`(1UE.jpg


 

其他型号推荐

 

ABBPCD530A102 3BHE041343R0102ABBLM80.AICS TRIPLEXT8403
KEBAFB201ABBDSAO120A 3BSE018293R1ICS TRIPL EXT8461
TRICONEX3504EABBUAC383AE01 HIEE300890R0001ICS TRIPL EXT8311
ABBPPC907BE 3BHE02457 7R0101ABBUAC389AE02 HIEE300888R0002DANFOSEEKC361
ABB .KUC755AE117 3BHB005243R0117ABBPPC907BE101 3BHE024577R0101TRICONEX3700A
GERS-FS9001 362A1052P404ABBPPC905AE101 3BHE014070R0101GEDS200DCFBG1BLC
国产02011602102三排96针GE20836416WOODWARD5233-2089
BENTLY3500/05-01-02-00-00-01GEESP10BICS TRIPLEXT8231
BENTLY3500/42M 176449-02GEITM11A8XJ036645GE44B714969(IC698CPE030,IC698CPE020 电池盖)
KONGSBERGRMP201-8GEVG5SK8I052311 PM0N2000ABBUFC921A101 3BHE024855R0101
EPROCON021GEHWA143-TDM-PMC-V20ICS TRIPL EXT8314
MOTOROLA5264GEESM10AWESTINGHOUSE1C31227G02
MOTOROLAL0115012 L0115032SCHNEIDERPC-E984-685

AUTOLIV627844200CHIMAH4135ABB  PM150V08 3BSE009598R1
AUTOLIVSim.Mod. B0760 627913600BHIMAH4135ATERASAKI ERC-244
KONGSBERGRMP201-8LAM810-370141-001ABBHIEE200038R0001
ABBCMA130 3DDE300410ABB5SHY3545L0010FOXBOROFBM214B P0927AH
WOODWARD8200- 1302FOXBOROFBMSVHHONEYWELL05701-A-0302